Search

Darren Thomsen Phones & Addresses

  • 6965 Mill Run Cir, Naples, FL 34109
  • s
  • 518 Bay Circle Dr, Warsaw, IN 46580 (574) 306-2397
  • Largo, FL
  • 2700 Grand Reserve Cir, Clearwater, FL 33759 (727) 723-7837
  • Tampa, FL
  • Gainesville, FL
  • Sarasota, FL
  • 518 Bay Circle Dr, Warsaw, IN 46580

Work

Company: Zimmer Aug 2010 Address: Warsaw, Indiana Position: Project manager/senior development engineer ii, global hip development

Education

School / High School: University of Florida 1998 to 2003

Skills

Medical Devices • Fda • Iso 13485 • R&D • Product Development • Product Launch • Quality System • Cross Functional Team Leadership • Design Control • Biomedical Engineering • Commercialization • Orthopedic • Design of Experiments • V&V • Validation • Design For Manufacturing • Biomaterials • Capa • Capital Equipment • Market Development • Lean Manufacturing • Fmea • Surgical Instruments • Manufacturing Engineering • Root Cause Analysis • Manufacturing • Orthopedics • Solidworks • Biomechanics • Gmp • Iso 14971 • Minitab • Six Sigma • Dmaic • Continuous Improvement • Verification and Validation • Corrective and Preventive Action • R • Injection Molding • Dfmea • Project Management • Biotechnology • Product Design • Finite Element Analysis • Mechanical Engineering • Regulatory Affairs • Fda Gmp • Regulatory Submissions • Surgery

Industries

Medical Devices

Resumes

Resumes

Darren Thomsen Photo 1

Senior Product Development Engineer

View page
Location:
6965 Mill Run Cir, Naples, FL 34109
Industry:
Medical Devices
Work:
Zimmer - Warsaw, Indiana since Aug 2010
Project Manager/Senior Development Engineer II, Global Hip Development

ConMed Linvatec Sep 2005 - Jul 2010
Product Development Engineer, R&D Sports Medicine

ConMed Linvatec Jul 2005 - Sep 2005
R&D Engineer

Uniiversity of Florida Jan 2003 - Jun 2005
Research Engineer

Sunset Mold Inc Feb 1996 - Aug 1998
Associate Manager
Education:
University of Florida 1998 - 2003
University of Florida 2003
Skills:
Medical Devices
Fda
Iso 13485
R&D
Product Development
Product Launch
Quality System
Cross Functional Team Leadership
Design Control
Biomedical Engineering
Commercialization
Orthopedic
Design of Experiments
V&V
Validation
Design For Manufacturing
Biomaterials
Capa
Capital Equipment
Market Development
Lean Manufacturing
Fmea
Surgical Instruments
Manufacturing Engineering
Root Cause Analysis
Manufacturing
Orthopedics
Solidworks
Biomechanics
Gmp
Iso 14971
Minitab
Six Sigma
Dmaic
Continuous Improvement
Verification and Validation
Corrective and Preventive Action
R
Injection Molding
Dfmea
Project Management
Biotechnology
Product Design
Finite Element Analysis
Mechanical Engineering
Regulatory Affairs
Fda Gmp
Regulatory Submissions
Surgery

Publications

Us Patents

Broaching Punch And Method Of Forming Bone Tunnels

View page
US Patent:
20100324562, Dec 23, 2010
Filed:
Jun 15, 2010
Appl. No.:
12/802820
Inventors:
Darren W. Thomsen - Largo FL, US
Robert Thibodeau - Saint Petersburg FL, US
International Classification:
A61B 17/16
US Classification:
606 80
Abstract:
A device and method for forming bone tunnels. The device has a conical tip with a spiral cutting edge intended to be pushed into the bone. After penetrating the bone to the desired depth the device is able to be rotated back out of the tunnel without excessive strain on the wall of the bone tunnel.

Suture Passing And Retrieval Device

View page
US Patent:
20090018554, Jan 15, 2009
Filed:
Jul 12, 2007
Appl. No.:
11/827515
Inventors:
Marc Thorne - Wakefield RI, US
Darren W. Thomsen - Largo FL, US
International Classification:
A61B 17/04
US Classification:
606145
Abstract:
A surgical instrument has a suture passer/advanoer and a suture retriever manipulated from a common handle. The retriever is preferably a loop that closes around the suture advanced through it by the advancer. The loop is retracted to draw it around the suture. The retriever has a fork like distal end to readily advance and let go of the suture after it is in the loop of the retriever. The advancer and retriever can be manipulated longitudinally and rotationally with respect to a tubular body through which they extend so that the suture retriever can be passed through a needle pierced through tissue to be sutured, the suture may be advanced and guided into the retriever loop to be gripped. Retracting the instrument will cause one end of the suture to be pulled retrograde through the tissue.

Instrument For Manual Insertion Of Button

View page
US Patent:
20180085110, Mar 29, 2018
Filed:
Sep 28, 2016
Appl. No.:
15/278804
Inventors:
- Naples FL, US
Pete Denove - Naples FL, US
Karen Gallen - Naples FL, US
Darren Thomsen - Naples FL, US
International Classification:
A61B 17/04
Abstract:
A button inserter includes a shaft having a fulcrum that extends beyond a distal tip of the shaft. An inner rod is within the shaft and has a button mating surface that extends from a distal tip of the inner rod. A handle includes a handle switch that translates the inner rod between an extended position where the button mating surface of the inner rod extends beyond the distal tip of the shaft and a retracted position where the button mating surface of the inner rod is located completely within the shaft.
Darren Wayne Thomsen from Naples, FL, age ~54 Get Report